Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 4.167
Filter
1.
Arq. bras. oftalmol ; 87(3): e2022, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1550037

ABSTRACT

ABSTRACT Purpose: To evaluate the saccadic movements of patients with visual field loss due to primary open-angle glaucoma. Methods: Thirteen patients with good visual acuity (0.2 logMAR or better) (seven patients with primary open-angle glaucoma 65 ± 13 years) and six controls (51 ± 6 years) yielded a comprehensive ophthalmological examination, including Humphrey Visual Field tests (SITA-Standard 24-2), and performed a monocular, exploratory digital visual search task that quantifies the duration for finding the number "4" on a random array of digits distributed on the screen. After individual adjustments of the angle and distance positioning, the screen was spatially matched with the 24-2 visual field, and divided into five areas for analysis. During the task, saccades were simultaneously recorded in the same eye with a video-based eye tracker. Results: The patients with primary open-angle glaucoma showed a significantly higher number of saccades/screen (median ± interquartile range, 59.00 ± 29.00 vs. 32.50 ± 19.75 saccades (p=0.027) and visual search time per screen (38.50 ± 60.14 vs. 23.75 ± 8.90 seconds (p=0.035) than the controls did. Although the univariate analysis indicated a significant correlation with visual field mean deviation (coefficient=26.19 (p=0.02), only the visual search time/screen was significantly associated with the number of saccades/screen in the multivariate regression model (coefficient=0.55 (p<0.001). Overall, no significant correlation was observed between the sectorial number of saccades and the sensitivity of the five visual field areas. Conclusions: The patients with primary open-angle glaucoma show impaired search performance and showed a higher number of saccades needed to find stimuli when performing the exploratory visual task.

2.
Dental press j. orthod. (Impr.) ; 29(1): e2423133, 2024. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1550224

ABSTRACT

ABSTRACT Objective: This study aimed to assess the frequency with which orthodontic patients decided to shift to another type of orthodontic appliance, among conventional metal brackets, ceramic brackets, lingual brackets and clear aligner, based on their personal experiences of pain, ulcers, bad breath, hygiene issues and social difficulties. Material and Methods: This study comprises of patients seeking orthodontic treatment. The sample (n = 500; age group = 19-25 years) was divided equally into four groups based on the treatment modality: conventional metal brackets, ceramic brackets, lingual brackets and clear aligner. Patients rated the questionnaire using a visual analogue scale, to assess variables (such as pain, ulcer etc) that impact various treatment modalities. Subsequently, patients from all groups provided feedback regarding their treatment experiences, and expressed their preference for an alternative modality. Intergroup comparison among the four groups was done using one-way analysis of variance with Tukey's HSD post-hoc test (p ≤ 0.05). Results: Patients who received lingual brackets reported higher levels of pain and ulceration, as compared to those who received clear aligners. All four groups showed statistically significant differences for ulcers during treatment (p ≤ 0.05). Of the 125 patients who received conventional metal brackets, 28% expressed a preference for clear aligner therapy, while 20% preferred ceramic brackets. In the lingual group, 56% of 125 patients preferred clear aligner therapy, and 8% preferred ceramic brackets to complete their treatment. In the ceramic group, 83% did not want to switch, whereas 17% desired to switch to clear aligner, while in aligner group no patient desired to switch. Conclusions: A higher percentage of patients from lingual brackets group chose to shift to clear aligners, followed by conventional metal brackets group and by ceramic brackets group, in this descending order. The clear aligner group demonstrated fewer issues than the other treatment modalities.


RESUMO Objetivo: Este estudo teve como objetivo avaliar a frequência com que pacientes ortodônticos decidiram mudar para outro tipo de aparelho ortodôntico, entre braquetes convencionais de metal, braquetes cerâmicos, braquetes linguais e alinhadores transparentes, com base em suas experiências pessoais de dor, aftas, mau hálito, problemas de higiene e dificuldades sociais. Material e Métodos: Esse estudo foi composto por pacientes que procuram tratamento ortodôntico. A amostra (n = 500; faixa etária = 19-25 anos) foi dividida igualmente em quatro grupos, com base na modalidade de tratamento: braquetes metálicos convencionais, braquetes cerâmicos, braquetes linguais e alinhadores transparentes. Os pacientes responderam a um questionário, usando uma escala visual analógica, para avaliar variáveis como dor e aftas, que impactam diferentes modalidades de tratamento. Posteriormente, os pacientes de todos os grupos forneceram feedback sobre suas experiências de tratamento e expressaram sua preferência por uma modalidade alternativa. A comparação intergrupos entre os quatro grupos foi feita usando análise de variância unidirecional com teste post-hoc HSD de Tukey (p ≤ 0,05). Resultados: Os pacientes que usaram braquetes linguais relataram níveis mais elevados de dor e aftas, em comparação com aqueles que usaram alinhadores transparentes. Todos os quatro grupos apresentaram diferenças estatisticamente significativas para aftas durante o tratamento (p ≤ 0,05). Dos 125 pacientes que usaram braquetes metálicos convencionais, 28% expressaram preferência pelo tratamento com alinhadores transparentes, enquanto 20% preferiram braquetes cerâmicos. No grupo com braquetes linguais, 56% dos 125 pacientes preferiram o tratamento com alinhadores transparentes e 8% preferiram braquetes cerâmicos para completar o tratamento. No grupo com braquetes cerâmicos, 83% não queriam trocar de tratamento, enquanto 17% desejavam mudar para os alinhadores transparentes; enquanto no grupo de alinhadores nenhum paciente desejou mudar. Conclusões: Uma porcentagem maior de pacientes do grupo com braquetes linguais optou pela mudança para alinhadores transparentes, seguido pelo grupo com braquetes metálicos convencionais e pelo grupo com braquetes cerâmicos, em ordem decrescente. O grupo de alinhadores transparentes demonstrou menos problemas do que as outras modalidades de tratamento.

3.
Arq. bras. oftalmol ; 87(2): e2022, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1533788

ABSTRACT

ABSTRACT A 71-year-old woman presented a non-arteritic anterior ischemic optic neuropathy in an optic nerve with previously registered superonasal peripapillary myelinated nerve fibers. Her past medical history was significant for controlled systemic hypertension, hyperlipidemia, and diabetes mellitus. The physiologic cup was absent in both optic discs. Non-arteritic anterior ischemic optic neuropathy mainly affected the temporal and inferior sectors of the peripapillary retinal nerve fiber layer, as could be demonstrated by retinal nerve fiber layer optical coherence tomography and optic disc optical coherence tomography angiography. Unlike other published reports, just a slight regression of the myelinated nerve fibers was observed after 1 year of follow-up. This occurred because ischemia mainly affected the temporal and inferior peripapillary sectors, whereas myelinated nerve fibers were superonasal to the optic disc.


RESUMO Uma mulher de 71 anos de idade apresentou neuropatia óptica isquêmica anterior não arterítica no nervo óptico com fibras nervosas peripapilares mielinizadas previamente registradas. Seu histórico médico foi significativo para hipertensão arterial sistêmica controlada, hiperlipidemia e diabetes mellitus. Em ambos os discos ópticos, a tacícula fisiológica esteve ausente. A neuropatia óptica isquêmica anterior não arterítica afetou principalmente os setores temporal e inferior da camada de fibras nervosas da retina peripapilar, como demonstrado pela tomografia de coerência óptica da camada de fibras nervosas da retina e pela angiotomografia de coerência óptica do disco óptico. Ao contrário de outros relatórios publicados, apenas uma ligeira regressão das fibras nervosas mielinizadas foi observada após um ano de acompanhamento. Isto pode ser explicado pelo fato da isquemia ter afetado principalmente os setores temporal e inferior peripapilares, enquanto as fibras nervosas de mielina eram nasal superior ao disco óptico.

4.
Arq. bras. oftalmol ; 87(2): e2022, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1533803

ABSTRACT

ABSTRACT Purpose: To describe a 2019 acute toxoplasmosis outbreak in the city of São Paulo, Brazil, and to evaluate the laboratory serological profile for toxoplasmosis for three consecutive years. The ophthalmological manifestations of the patients involved in the outbreak were also studied. Methods: A cross-sectional descriptive study of a toxoplasmosis outbreak in São Paulo, Brazil, between February and May 2019. Epidemiological data were described, as were the observed ocular manifestations. As part of this study the number of patients with positive IgM toxoplasmosis serology was obtained from a large laboratory network (DASA) for three consecutive years, including the year of the outbreak (2018, 2019, 2020). Results: Eighty-three individuals were identified in the outbreak and two clusters were studied. The clinical picture of at least 77% of the patients, the epidemiological analysis, and the short incubation period (5-8 days) suggested contamination by oocysts. Serological laboratory data analysis revealed an increase of positive toxoplasmosis IgM in 2019 of 73% compared to the previous year. Ophthalmological examination revealed that at least 4.8% of the patients developed toxoplasmic retinochoroiditis, none of whom had been treated during the acute systemic disease. Conclusion: Our findings indicate vegetable contamination as the possible source of this outbreak, a high prevalence of toxoplasmosis in São Paulo during the outbreak period, and a drop in the number of tests during the COVID-19 pandemic. Retinochoroiditis was observed in at least 4.8% of the cases. We confirm the need to implement effective means for the prevention, diagnosis, and treatment of the disease. This may involve raising awareness among the population of the importance of vegetable hygiene, and improved quality control of food and water.

5.
Arq. bras. oftalmol ; 87(2): e2023, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1533807

ABSTRACT

ABSTRACT Purpose: To investigate the association of pre--photorefractive keratectomy Schirmer-1 test value with post--photorefractive keratectomy central corneal epithelial thickness, ocular surface disease index score, and uncorrected distance visual acuity. Methods: Patients were categorized according to preoperative Schirmer-1 value: the normal Schirmer Group (n=54; Schirmer-1 test value, >10 mm) and the low Schirmer Group (n=52; Schirmer-1 test value, between 6 and 10 mm). We analyzed ablation depth, visual acuity, result of Schirmer-1 test (with anesthesia), tear film break-up time, ocular surface disease index score, central corneal epithelial thickness, and spherical equivalent refraction. Results: We found significant differences between the groups in Schirmer-1 test value, tear film break-up time, and ocular surface disease index score, both preoperatively and postoperatively (p<0.001). The preoperative central corneal epithelial thicknesses of the two groups were similar (p>0.05). After photorefractive keratectomy, the Schirmer-1 test value and spherical equivalent refraction decreased in both groups (p<0.05), and ocular surface disease index scores and central corneal epithelial thickness values increased in the low Schirmer Group (p<0.001) but not in the normal Schirmer Group (p>0.05). The postoperative central corneal epithelial thicknesses of the low Schirmer Group were significantly higher than those of the normal Schirmer Group (p<0.001). Postoperative uncorrected distance visual acuity did not differ significantly between the two groups (p>0.05). Conclusions: In patients with low Schirmer-1 test values before photorefractive keratectomy, the corneal epithelium thickened and ocular surface complaints increased during the postoperative period. However, changes in the corneal epithelium did not affect the postoperative uncorrected distance visual acuity. To reduce postoperative problems on the ocular surface in these patients, we recommend that dry eye be treated before photorefractive keratectomy.

6.
BrJP ; 7: e20240005, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1533970

ABSTRACT

ABSTRACT BACKGROUND AND OBJECTIVES: Lumbar disorders, which contribute to significant workplace absenteeism and chronic disability, are associated with a considerable financial and social burden. Although a conservative approach provides satisfactory pain relief, biomechanical improvement and is associated with a low risk of adverse effects, there is lack of consensus in the literature regarding the best therapeutic strategy in such cases. METHODS: This retrospective longitudinal study used secondary data from the institutional medical records of patients who completed a multidisciplinary program for the treatment of low back pain between 2019 and 2021. Data regarding pain levels and motor skills were obtained from patients who completed the care program at a private hospital in Bento Gonçalves, RS. The following step-wise treatment algorithm was used: evaluation by a specialist physician for the etiological diagnosis of pain, pharmacological management and dry needling, followed by standard rehabilitation intervention performed by the physiotherapy team and exercises by the physical education team. The visual analogue scale (VAS) was used to measure pain at the start and at the completion of the intervention, and the Oswestry Disability Index (ODI) was used to measure motor skills at the start and at 6 and 12 months following the multiprofessional intervention for rehabilitation. RESULTS: A reduction in pain and motor disability in patients who completed all stages of the treatment program was observed. Pain by the VAS presented the following scores: baseline 7 [5-8] and after treatment 2 [0-4]; and the scores of the ODI were: at baseline 0.34 [0.26 - 0.40], at 6 months 0.16 [0.08 - 0.26] and after treatment 0.12 [0.04 - 0.21]. CONCLUSION: The treatment program reduced the pain and disability associated with low back pain and can serve as the basis for further studies carried out to confirm the effectiveness of this intervention.


RESUMO JUSTIFICATIVA E OBJETIVOS: As doenças lombares, que contribuem para um absenteísmo significativo no local de trabalho e para a incapacidade crônica, estão associadas a um encargo financeiro e social considerável. Embora a abordagem conservadora proporcione alívio satisfatório da dor, melhore a biomecânica e esteja associada a baixo risco de efeitos adversos, não há consenso na literatura sobre a melhor estratégia terapêutica nesses casos. MÉTODOS: Neste estudo longitudinal retrospectivo, foram utilizados dados secundários dos prontuários médicos institucionais de pacientes que completaram um programa multidisciplinar para tratamento de dor lombar entre 2019 e 2021. Dados sobre níveis de dor e habilidades motoras foram obtidos de pacientes que completaram o programa assistencial de um hospital privado de Bento Gonçalves, RS. Foi utilizado o seguinte tratamento passo a passo: avaliação por médico especialista para diagnóstico etiológico da dor, manejo farmacológico e agulhamento a seco, seguido de intervenção de reabilitação padrão realizada pela equipe de fisioterapia e exercícios pela equipe de educação física. A escala analógica visual (EAV) foi utilizada para medir a dor no início e após a conclusão da intervenção, e o Índice de Incapacidade de Oswestry (ODI) foi usado para medir as habilidades motoras no início e aos 6 e 12 meses após a intervenção multiprofissional para reabilitação. RESULTADOS: Observou-se redução na dor e na incapacidade motora em pacientes que completaram todas as etapas do programa de tratamento. A intensidade da dor medida pela EAV apresentou as seguintes pontuações: basal 7 [5-8] e após tratamento 2 [0-4]; enquanto o ODI apresentou as pontuações: basal 0,34 [0,26 - 0,40], até 6 meses 0,16 [0,08 - 0,26] e após o tratamento 0,12 [0,04 - 0,21]. CONCLUSÃO: O programa de tratamento reduziu a dor e a incapacidade associadas à dor lombar e pode servir de base para novos estudos realizados para confirmar a eficácia desta intervenção.

7.
Cogitare Enferm. (Online) ; 29: e92082, 2024. graf
Article in Portuguese | LILACS-Express | LILACS, BDENF | ID: biblio-1534257

ABSTRACT

RESUMO Objetivo: Desenvolver tecnologias educacionais sobre pré-natal com e para mulheres deficientes visuais. Método: Estudo metodológico com interface participativa e abordagem qualitativa. Realizado em uma Unidade Técnica Especializada no município de Belém, Pará, Brasil. A produção de dados ocorreu entre agosto e setembro de 2021 com seis mulheres. Utilizou-se o DOSVOX como recurso de comunicação para que as participantes respondessem quatro instrumentos com vistas ao desenvolvimento das tecnologias. A análise foi de conteúdo temático. Resultados: As mulheres com deficiência visual querem respeito à sua autonomia, inclusão e informação dos profissionais. As tecnologias produzidas apontam as demandas específicas de mulheres com deficiência visual e a importância de preservar a autonomia durante a realização do pré-natal. Conclusão: Tecnologias produzidas de forma participativa apontam perspectivas e necessidades específicas das mulheres sobre o pré-natal e poderão subsidiar tanto o agir dos enfermeiros nas consultas como favorecer mulheres com deficiência visual durante o pré-natal.


ABSTRACT Objective: To develop educational technologies on prenatal care with and for visually impaired women. Method: A methodological study with a participatory interface and qualitative approach. It was carried out at a Specialized Technical Unit in the municipality of Belém, Pará, Brazil. Data production took place between August and September 2021 with six women. DOSVOX was used as a communication resource for the participants to answer four instruments with a view to developing the technologies. The analysis was of the thematic content type. Results: Women with visual impairment want respect for their autonomy, inclusion, and information from the professionals. The technologies produced point to the specific demands of visually impaired women and to the importance of preserving autonomy during prenatal care. Conclusion: Technologies produced in a participatory way point out women's specific perspectives and needs regarding prenatal care and may support both the nurses' actions in consultations and favor women with visual impairment during prenatal care.


RESUMEN Objetivo: Desarrollar tecnologías educativas sobre el control prenatal con y para mujeres con discapacidad visual. Método: Estudio metodológico con interfaz participativa y enfoque cualitativo. Realizado en una Unidad Técnica Especializada de la ciudad de Belém, Pará, Brasil. La producción de datos se realizó entre agosto y septiembre de 2021 con seis mujeres. Se utilizó DOSVOX como recurso de comunicación para que las participantes respondieran a cuatro instrumentos a fin de desarrollar las tecnologías. El análisis fue de contenido temático. Resultados: Las mujeres con discapacidad visual quieren que se respete su autonomía, inclusión e información por parte de los profesionales. Las tecnologías creadas ponen de manifiesto las demandas específicas de las mujeres con discapacidad visual y la importancia de preservar la autonomía durante el control prenatal. Conclusión: Las tecnologías creadas de manera participativa señalan las perspectivas y necesidades específicas de las mujeres con respecto al cuidado prenatal y pueden ayudar a los enfermeros en las consultas y a las mujeres con discapacidad visual durante el control prenatal.

8.
Arq. bras. oftalmol ; 87(3): e2022, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1520225

ABSTRACT

ABSTRACT Purpose: This study aimed to examine the effects of unilateral corneal collagen cross-linking treatment on visual acuity and the topographic findings of the fellow untreated eye of patients who had bilateral progressive keratoconus. Methods: Patients with progressive keratoconus who underwent cross-linking treatment were screened retrospectively. A total of 188 untreated eyes of 188 patients whose eyes were treated unilaterally with either standard or accelerated cross-linking and refused cross-linking procedure for the fellow eye were included. Visual acuity and topographic findings of the fellow untreated eyes were obtained preoperatively and postoperatively at the 1st, 3rd, 6th, 12th, 24th, 30th, and 36th months. Results: The change over time of variables examined was similar in the untreated eyes of patients who received standard and accelerated cross-linking methods (p>0.05). At the 12th month, 136 (95.8%) untreated eyes were stable according to progression criteria. Only 4 (8%) eyes were progressive at the 24th month. No progression was observed in any of the 16 patients with a 36-month follow up. Conclusions: The results showed that the fellow untreated eyes of patients with bilateral progressive keratoconus did not have significant progression rates after unilateral cross-linking treatment.


RESUMO Objetivo: Examinar os efeitos do tratamento de reticulação unilateral do colágeno corneano na acuidade visual e os achados topográficos em olhos não tratados de pacientes com ceratocone progressivo bilateral. Métodos: Foram rastreados retrospectivamente pacientes com ceratocone progressivo submetidos a tratamento de reticulação. Foram incluídos no estudo 188 olhos não tratados de 188 pacientes tratado unilateralmente com reticulação padrão ou acelerada e que recusaram o procedimento de reticulação no outro olho. A acuidade visual e os achados topográficos dos olhos não tratados foram obtidos no pré- e pós-operatório no 1º, 3º, 6º, 12º, 24º, 30º e 36º mês. Resultados: As alterações ao longo do tempo foram semelhantes para as variáveis examinadas nos olhos não tratados de pacientes tratados com métodos de reticulação padrão e acelerado (p>0,05). No 12º mês, 136 olhos não tratados (95,8%) estavam estáveis, de acordo com os critérios de progressão. Apenas quatro olhos (8%) mostraram progressão no 24º mês. Nenhuma progressão foi observada nos 16 pacientes que tiveram um acompanhamento de 36 meses. Conclusões: O estudo mostrou que os olhos não tratados de pacientes com ceratocone progressivo bilateral não apresentaram taxas de progressão significativas após o tratamento unilateral com reticulação.

9.
Arq. bras. oftalmol ; 87(3): e2022, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1520226

ABSTRACT

ABSTRACT Purposes: This study aimed to determine the association of the long-term refractive outcomes of cataract surgery with self-reported visual function obtained using Catquest-9SF. Methods: Patients recruited from the cataract outpatient clinic of VER MAIS Oftalmologia underwent a complete ophthalmologic examination. Patients who were diagnosed with cataract with indications for phacoemulsification and intraocular lens implantation received the Catquest-9SF questionnaire before and after surgery at 30 days and 1 year. Results: A total of 133 patients were recruited, but 32 patients were lost to follow-up; finally, data from 101 patients (48 men, 53 women) were analyzed. The crude variance explained by the data was 69.9%, and the unexplained variance in the first contrast was 2.39 eigenvalues (>2); thus, these results are different from those expected from random data. The people separation index was 2.95 (>2), and the people trust value was 0.9 (>0.8). These indices were evaluated in the assessment of skill levels. Visual acuity was the main variable that correlated with the Catquest score. Conclusions: The Catquest-9SF translated into Portuguese proved to be a one-dimensional and psychometrically valid tool to assess visual dysfunction in patients with cataract, and it is successful in objectively quantifying improvements after surgery. The results of this tool could be predictive and concordant of visual acuity improvement.


RESUMO Objetivo: Associar os resultados refrativos a longo prazo da cirurgia de catarata e a função visual autorreferida pelo questionário Catquest-9SF. Métodos: Paciente recrutados no ambulatório de catarata da VER MAIS Oftalmologia, foram submetidos a exame oftalmológico completo. Após diagnóstico de catarata com indicação de tratamento cirúrgico com facoemulsificação e implante de lente intraocular, o questionário foi aplicado antes da intervenção, 30 dias após cirurgia e 1 ano após, novamente. Resultados: Foram recrutados 133 pacientes. No decorrer do seguimento, 32 pacientes foram perdidos e ao final foram analisados os dados de 101 pacientes, dos quais 48 foram homens e 53 foram mulheres. A variância bruta explicada por dados foi de 69,9% e a inexplicada em primeiro contraste por 2,39 eigenvalores, sendo maior que 2, o que nos mostra que são resultados differentes dos esperados de dados aleatórios. O índice de separação de pessoas foi de 2.95 (>2) e o valor de confiança de pessoas foi de 0,9 (>0,8). Estes índices são os valores mínimos aceitáveis na diferenciação de níveis de habilidade. Acuidade visual foi a principal variável correlacionada com o score do Catquest. Conclusões: O Catquest-9SF traduzido para o português se demonstrou unidimensional e uma ferramenta psicometricamente válida para avaliar disfunção visual em pacientes com catarata, além de ter tido sucesso para quantificar objetivamente melhoras após a intervenção cirúrgica. Essa ferramenta pode ser utilizada como preditiva e concordante da melhora da acuidade visual.

10.
Arq. bras. oftalmol ; 87(4): e2022, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1520232

ABSTRACT

ABSTRACT Purpose: To compare the differences between the apparent and actual chord μ. Methods: In this prospective, comparative, non-randomized, and non-interventional study, imaging examinations using Pentacam and the HD Analyzer were performed in the same room under the same scotopic conditions. The inclusion criteria were patients aged 21-71 years, able to provide informed consent, myopia up to 4D, and anterior topographic astigmatism up to 1D. Patients using contact lenses, those with previous eye diseases or surgeries, corneal opacities, corneal tomographic changes, or suspected keratoconus were excluded. Results: Altogether, 116 eyes of 58 patients were analyzed. The patients' mean age was 30.69 (±7.85) years. In the correlation analyses, Pearson's correlation coefficient of 0.647 indicates a moderate positive linear relationship between apparent and actual chord μ. The mean actual and apparent chord μ were 226.21 ± 128.53 and 278.66 ± 123.90 μm, respectively, with a mean difference of 52.45 μm (p=0.01). The analysis of mean pupillary diameter resulted in 5.76 mm using the HD Analyzer and 3.31 mm using the Pentacam. Conclusions: We found a correlation between the two measurement devices, and even though we found considerable differences, both can be used in daily practice. Given their differences, we should respect their peculiarities as well.


RESUMO Objetivo: Comparar as diferenças entre a chord aparente μ e o chord real μ. Métodos: Estudo prospectivo, comparativo, não randomizado e não intervencionista. Os exames de imagem (Pentacam e HD Analyzer) foram realizados na mesma sala e nas mesmas condições escotópicas. Os critérios de inclusão foram idade de 21 a 71 anos; compreensão do termo de consentimento; miopia até 4D e astigmatismo topográfico anterior até 1D. Os critérios de exclusão foram usuários de lentes de contato; pacientes com doenças oculares prévias ou cirurgias; opacidades da córnea; a presença de alterações tomográficas da córnea ou suspeita de ceratocone. Resultados: Em nosso estudo foram analisados 116 olhos de 58 pacientes. A média de idade foi de 30,69 anos (± 7,85). Análises de correlação foram desenvolvidas e o coeficiente de correlação de Pearson (0,647) indica uma relação linear positiva moderada entre as variáveis. A média do chord μ real foi 226,21 ± 128,53 μm e a média do chord μ média foi 278,66 ± 123,90 μm, com diferença média de 52,45 μm (p=0,01). A análise do diâmetro pupilar médio apresentou: 5,76mm no HD Analyzer e 3,31mm no Pentacam. Conclusões: Entendemos a existência de uma diferença significativa entre os métodos e assim a medida de ambos os dispositivos com base em princípios diferentes devemos respeitar suas peculiaridades. Como encontramos correlação entre as duas medidas, acreditamos que ambas podem ser utilizadas na prática diária.

11.
Arq. bras. oftalmol ; 87(4): e2021, 2024. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1520235

ABSTRACT

ABSTRACT We present an unusual case of a 13-year-old male pediatric patient with a diagnosis of sphenoid sinus mucocele. The patient suffered a progressive loss of visual acuity over three months followed by a total recovery of his visual acuity after surgery. The patient presented at the emergency room complaining of progressive loss of visual acuity in his left eye which decreased to hand motion over the preceding months. Imaging studies revealed a cystic mass, suggestive of sphenoid sinus mucocele, which was causing compressive optic neuropathy and proptosis. The patient was scheduled for a sphenoidectomy and resection of the mass. Three days after surgery, the patient's visual acuity in the left eye was 20/20, indicating complete recovery from his symptoms. We suggest that the excellent outcome in this patient may be attributable to his age. His ongoing physical development might have been the decisive factor in the recovery of his visual acuity following compressive optic neuropathy secondary to sphenoid sinus mucocele. Further research is needed to verify this proposed explanation.


RESUMO Apresentamos um caso incomum de paciente pediátrico com diagnóstico de mucocele de seio esfenoidal, que apresentou perda progressiva da acuidade visual ao longo de três meses, resultando em recuperação total da acuidade visual após a cirurgia. Paciente do sexo masculino, 13 anos, procurou o pronto-socorro, queixando-se de perda progressiva da acuidade visual do olho esquerdo nos últimos três meses. Exames de imagem revelaram uma massa cística sugestiva de mucocele de seio esfenoidal, causando neuropatia óptica compressiva e proptose. O paciente foi agendado para esfenoidectomia e ressecção da massa. Três dias após a cirurgia, a acuidade visual do paciente no olho esquerdo era de 20/20, apresentando recuperação completa dos sintomas. Diante dos resultados de nosso paciente, sugerimos que a idade do paciente pode ser decisiva na recuperação da acuidade visual de uma neuropatia óptica compressiva secundária à mucocele de seio esfenoidal. Mais pesquisas são necessárias para verificação desses dados.

12.
Arq. bras. oftalmol ; 87(6): e2022, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1520244

ABSTRACT

ABSTRACT Purpose: As digital devices are increasingly used at work, valid and reliable tools are needed to assess their effect on visual health. This study aimed to translate, cross-culturally adapt, and validate the Computer Vision Syndrome Questionnaire (CVS-Q©) into Portuguese. Methods: A 5-phase process was followed: direct translation, synthesis of translation, back-translation, consolidation by an expert committee, and pretest. To run the pretest, a cross-sectional pilot study was conducted with 26 participants who completed the prefinal Portuguese version of the CVS-Q© and were asked about difficulties, comprehensibility, and suggestions to improve the questionnaire. To evaluate the reliability and validity of the Portuguese version of the CVS-Q©, a cross-sectional validation study was performed in a different sample (280 workers). Results: In the pretest, 96.2% had no difficulty in completing it, and 84.0% valued it as clear and understandable. CVS-Q© in Portuguese (Questionário da Síndrome Visual do Computador, CVS-Q PT©) was then obtained. Validation revealed the scale's good internal consistency (Cronbach's alpha=0.793), good temporal stability (intraclass correlation coefficient=0.847; 95% CI 0.764-0.902, kappa=0.839), adequate sensitivity and specificity (78.5% and 70.7%, respectively), good discriminant capacity (area under the curve=0.832; 95% CI 0.784-0.879), and adequate convergent validity with the ocular surface disease index (Spearman correlation coefficient=0.728, p<0.001). The factor analysis provided a single factor accounting for 37.7% of the explained common variance. A worker who scored ≥7 points would have computer vision syndrome. Conclusions: CVS-Q PT© can be considered an intuitive and easy-to-understand tool with good psychometric properties to measure computer vision syndrome in Portuguese workers exposed to digital devices. This questionnaire will assist in making decisions on preventive measures, interventions, and treatment and comparing exposed populations in different Portuguese-speaking countries.


RESUMO Objetivos: À medida que a utilização de equipamentos digitais no emprego aumenta, a avaliação do seu efeito na saúde visual necessita de ferramentas válidas e robustas. Este estudo teve como objetivo traduzir, adaptar culturalmente e validar para português o Questionário da Síndrome Visual do Computador (CVS-Q©). Métodos: O procedimento foi realizado em 5 fases: tradução direta, síntese da tradução, tradução inversa, consolidação por um painel de especialistas, e pré-teste. Para fazer o pré-teste foi realizado um estudo piloto transversal aplicado a uma amostra de 26 participantes que completaram a versão pré-final da versão portuguesa do CVS-Q©, questionando por dificuldades, compreensão e sugestões de melhoria do questionário. Para avaliar a confiança e validade da versão portuguesa do CVS-Q© foi realizado um estudo transversal de validação em uma amostra diferente (280 funcionários). Resultados: No préteste, 96.2% dos participantes não apresentaram dificuldades no preenchimento do questionário, enquanto 84.0% indicaram que era claro e compreensível. Obteve-se, então, o CVS-Q© em português (Questionário da Síndrome Visual do Computador, CVS-Q PT©). A sua validação revelou uma boa consistência interna da sua escala (Cronbach's alpha=0.793), boa estabilidade tem poral (coeficiente de correlação interclasse=0.847; 95% CI 0.764-0.902, kappa=0.839), sensibilidades e especificidades adequadas (78.5% e 70.7%, respetivamente), boa capacidade de discriminação (área abaixo da curva=0.832; 95% CI 0.784-0.879), e uma adequada validade da convergência com o índice de doença da superfície ocular (ocular surface disease index - OSDI; coeficiente de correlação de Spearman=0.728, p<0.001). A análise fatorial revelou um único fator responsável por explicar a variância comum em 37.7%. Um funcionário com uma pontuação ≥7 pontos sofria de síndrome visual do computador. Conclusão: O CVS-Q PT© pode ser considerada uma ferramenta intuitiva, de fácil interpretação e com boas pro priedades psicométricas para avaliar a síndrome visual do computador em funcionários portugueses expostos a ecrãs digitais. Este questionário facilitará as decisões sobre medidas preventivas, intervenções e tratamento, e a comparação entre as populações expostas em diferentes países de língua portuguesa.

13.
Arq. bras. oftalmol ; 87(1): e2021, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1527816

ABSTRACT

ABSTRACT Purpose: To evaluate the effect of tobacco smoking on trabeculectomy outcomes. Methods: Charts of patients with glaucoma who underwent trabeculectomy performed by a single surgeon between 2007 and 2016 were retrospectively reviewed. Charts were screened for a documented history of smoking status before surgery. Demographic and clinical preoperative variables were recorded. Based on smoking history, subjects were divided into two groups: smokers and nonsmokers. Any bleb-related interventions (e.g., 5-flourouracil injections ± laser suture lysis) or bleb revision performed during the postoperative period were noted. Success was defined as an intraocular pressure >5 mmHg and <21 mm Hg without (complete success) or with (qualified success) the use of ocular hypotensive medications. Failure was identified as a violation of the criteria mentioned above. Results: A total of 98 eyes from 83 subjects were included. The mean age of the subjects was 70.7 ± 11.09 years, and 53% (44/83) were female. The most common diagnosis was primary open-angle glaucoma in 47 cases (47.9%). The smokers Group included 30 eyes from 30 subjects. When compared with nonsmokers, smokers had a significantly worse preoperative best-corrected visual acuity (p=0.038), greater central corneal thickness (p=0.047), and higher preoperative intraocular pressure (p=0.011). The success rate of trabeculectomy surgery at 1 year was 56.7% in the smokers Group compared with 79.4% in the Group nonsmokers (p=0.020). Smoking presented an odds ratio for failure of 2.95 (95% confidence interval, 1.6-7.84). Conclusion: Smokers demonstrated a significantly lower success rate 1 year after trabeculectomy compared with nonsmokers and a higher requirement for bleb-related interventions.


RESUMO Objetivo: Avaliar o efeito do tabagismo nos desfechos da trabeculectomia. Métodos: Uma revisão retrospectiva do gráfico de pacientes com glaucoma submetidos à trabeculectomia foi realizada por um único cirurgião entre 2007 e 2016. Os gráficos foram examinados para uma história documentada de condição de fumante antes da cirurgia. Variáveis pré-operatórias clínicas e demográficas e clínicas foram registradas. Os pacientes foram divididos em dois grupos de acordo com sua história de tabagismo em fumantes e não fumantes. Quaisquer Intervenções relacionadas à bolha, por exemplo, injeções de 5-fluorouracil + lise de sutura com laser, ou revisão da bolha realizada durante o período pós-operatório foram observadas. O sucesso foi definido como pressão intraocular > 5 mmHg e < 21 mm Hg sem (sucesso completo) ou com (sucesso qualificado) medicamentos hipotensores oculares. A falha foi identificada como violação dos critérios mencionados acima. Resultados: O estudo incluiu 98 olhos de 83 pacientes com idade média de 70,7 ± 11,09 anos, sendo 53% (44/83) dos pacientes do sexo feminino. O diagnóstico mais comum foi o glaucoma de ângulo aberto primário com 47 casos (47,9%). O Grupo de fumantes incluiu 30 olhos de 30 pacientes. Os fumantes, quando comparados aos não fumantes, apresentaram uma melhor acuidade visual pré-operatória significativamente pior (p=0,038), maior espessura central da córnea (p=0,047) e maior pressão intraocular pré-operatória (p=0,011). A taxa de sucesso de um ano para a cirurgia de trabeculectomia foi de 56,7% no Grupo de fumantes contra 79,4% no Grupo de não fumantes (p=0,020). O tabagismo apresentou razão de chances para falha de 2,95 95% de IC (1,6-7,84). Conclusão: Os fumantes demonstraram uma taxa de sucesso significativamente menor em um ano após a trabeculectomia em comparação com os não fumantes e uma maior necessidade de intervenções relacionadas à bolha.

14.
Arq. bras. oftalmol ; 87(1): e2021, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1527817

ABSTRACT

ABSTRACT Keratoconus is a progressive disorder that manifests as a cone-like steepening of the central or paracentral inferior cornea and irregular stromal thinning. There is a gradual decrease in visual acuity due to corneal asymmetry, irregular astigmatism, and increased optical aberrations, consequently impacting the quality of life. Several procedures have been developed in an attempt to slow or reverse the progression. The Bader procedure, which includes a pattern of incisions around the circumference of the cornea and at the base of the protruding cone, is one such surgery. These incisions penetrate 70-90% of the cornea's depth. Its goal is to flatten the topography and reduce corneal asymmetry and irregular astigmatism. Though prior research found these to be highly promising, we report a patient who was given contact lenses to restore and maintain his vision while his corneal ectasia and thinning progressed over the following decade.


RESUMO O ceratocone é uma doença progressiva que se manifesta como uma elevação semelhante a um cone da cór­nea central ou paracentral inferior e é associada a uma re­dução irregular da espessura do estroma. Há uma diminuição gradual da acuidade visual devido à assimetria da córnea, ao astigmatismo irregular e a um aumento das aberrações ópticas, o que prejudica a qualidade de vida. Foram desenvolvidos vários procedimentos para tentar interromper ou mesmo reverter a evolução da doença. Um deles é o chamado procedimento de Bader, que inclui um padrão de incisões em volta da circunferência da córnea e na base do cone protuberante. Essas incisões penetram até 70%-90% da profundidade da córnea e têm o objetivo de achatar a topografia e diminuir a assimetria da córnea e o astigmatismo irregular. Embora essa técnica seja muito promissora, segundo um estudo anterior, aqui se apresenta o caso de um paciente no qual esses objetivos não foram atingidos. Esse paciente recebeu lentes de contato para restaurar e manter sua visão, enquanto sua ectasia corneana e a redução da espessura progrediram ao longo da década seguinte.

15.
Arq. bras. oftalmol ; 87(1): e2021, 2024. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1527819

ABSTRACT

ABSTRACT This article reports the case of an 11-year-old male patient with a history of proptosis and low progressive visual acuity in the left eye. He presented with a best corrected visual acuity of 20/25 in the right eye and light perception in the left eye. Exotropia and limitation in adduction were observed in the left eye. On automated perimetry, inferiortemporal quadrantopsia was observed in the right eye, while total scotoma was observed in the left eye. On magnetic resonance imaging, there was an expansive lesion in the left optic nerve, extending to the brainstem with chiasmatic involvement. This article aims to report a case of optic pathway glioma, as well as to discuss its clinical findings and their interconnection with the current literature.


RESUMO Este artigo relata o caso de um paciente do sexo masculino, 11 anos de idade, com história de proptose e baixa de acuidade visual progressiva. Ao exame oftalmológico apresentava melhor acuidade visual de 20/25 em olho direito e percepção de luz em olho esquerdo. Existia exotropia e limitação à adução no olho esquerdo. À campimetria automatizada, observou-se quadrantopsia temporal inferior em olho direito e escotoma total em olho esquerdo. À ressonância magnética, evidenciou-se lesão expansiva em trajeto do nervo óptico esquerdo estendendo-se até região do tronco encefálico, com acometimento quiasmático. O objetivo deste artigo é relatar o glioma de vias ópticas, bem como discutir os achados e sua interligação com a literatura atual.

16.
Arq. bras. oftalmol ; 87(1): e2021, 2024. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1527824

ABSTRACT

ABSTRACT Purpose: To assess the anterior and posterior segments of full-term neonates over a 1.5-year period. Methods: The findings of full-term neonates who underwent ophthalmological examinations between June 2019 and December 2020 were analyzed, and the results were retrospectively recorded. Results: The study comprised 2972 neonates with a mean birth week of 38.7 ± 1.2 weeks and a mean birth weight of 3235 ± 464 g. The neonates were examined on an average of 49.3 ± 18.9 postnatal days. Of the examined neonates, 185 (6.2%) showed abnormal ophthalmological findings, the most prevalent of which were retinal hemorrhage in 2.3% (n=68) and white changes in the peripheral retina in 1.9% (n=55) of the neonates. Cases of optic disc pathologies (n=20), choroidal nevus (n=10), iris-choroidal coloboma (n=5), subconjunctival hemorrhage (n=6), non-specific retinal pigmentary change (n=4), congenital cataract (n=3), posterior synechia (n=3), iris nevus (n=3), corneal opacity (n=1), choroidal coloboma (n=1), iris coloboma (n=1), buphthalmos (n=1), anophthalmos (n=1), microphthalmia (n=1), lid hemangioma (n=1), and vitreous hemorrhage (n=1) collectively accounted for approximately 2% of all neonates. Pathologies that could potentially impair vision, which were detected by ophthalmological examination, accounted for 1.2% of all neonates (n=37). Conclusion: The most prevalent finding of the ophthalmological examinations of neonates in the present study was retinal hemorrhage. Ophthalmological examinations of neonates can help in identifying diseases that may affect their vision and are curable or may lead to amblyopia in the long term.


RESUMO Objetivo: Avaliar os segmentos anterior e posterior em recém-nascidos a termo durante um período de 1,5 anos. Métodos: Foram analisados recém-nascidos a termo que tiveram os olhos examinados entre junho de 2019 e dezembro de 2020, e os resultados foram registrados retrospectivamente. Resultados: O estudo foi composto por 2.972 recém-nascidos com média de uma semana de nascimento de 38,7 ± 1,2 semanas e um peso médio ao nascer de 3235 ± 464 g. Os recém-nascidos foram examinados em média pós-natal de 49,3 ± 18,9 dias. Dos recém-nascidos, 185 (6,2%) apresentaram resultados oculares anormais. Os achados oculares anormais mais prevalentes foram hemorragia da retina em 2,3% (n=68) e alterações brancas na retina periférica em 1,9% (n=55) dos recém-nascidos. Casos de patologias de disco óptico (n=20), nevo de coroide (n=10), coloboma iris-coroide (n=5), hemorragia subconjuntival (n=6), alteração pigmentar da retina não específica (n=4), catarata congênita (n=3), Sinequia posterior (n=3), nevo da íris (n=3), opacidade da córnea (n=1), coloboma de coroide (n=1), coloboma de íris (n=1), buftalmos (n=1), anoftalmia (n=1), microftalmia (n=1), hemangioma de pálpebra (n=1) e hemorragia vítrea (n=1) contabilizaram coletivamente cerca de 2% dos recém-nascidos. As patologias que potencialmente prejudicam a visão, detectadas por exame ocular, representaram 1,2% dos recém-nascidos (n=37). Conclusão: O achado mais prevalente de exames oculares de recém-nascidos neste estudo foi hemorragia da retina. Exames oftalmológicos em recém-nascidos podem ser úteis na identificação de doenças que podem impactar a visão deles, podendo ser curáveis ou levar à ambliopia no longo prazo.

17.
Arq. bras. oftalmol ; 87(2): e2021, 2024. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1527833

ABSTRACT

ABSTRACT A 59-year-old man presented with a unilateral blurring of vision in his left eye. His left eye's visual acuity was hand movements level. He underwent phacoemulsification surgery, and an intrastromal posterior chamber intraocular lens was implanted. The intrastromal intraocular lens was extracted and a new intraocular lens was implanted. Usinge the Snellen chart, the final best-corrected visual acuity was 20/40. With this case report, we wish to emphasize that a single stepwise clear corneal incision merged with wound-assisted intraocular lens injections can result in intraocular lens misdirection into the corneal stroma. As a result, while performing a misdirected intraocular lens removal, we recommend that the wound be carefully constructed.


RESUMO Um homem de 59 anos apresentou embaçamento visual unilateral no olho esquerdo. Sua acuidade visual nesse olho era no nível de movimentos da mão. O paciente havia se submetido a uma cirurgia de facoemulsificação em que foi feita a implantação intraestromal de uma lente intraocular de câmara posterior. Foi feita a extração dessa lente intraestromal intraocular e uma nova lente intraocular foi implantada. A melhor acuidade visual corrigida final foi de 20/40 pela tabela de Snellen. Com este relato de caso, os autores desejam apontar que uma incisão de degrau único em córnea clara, quando combinada com a injeção de uma lente ocular através da incisão, pode levar a um direcionamento incorreto da lente intraocular para dentro do estroma corneano. Portanto, recomenda-se uma construção cuidadosa da incisão ao se remover uma lente intraocular direcionada incorretamente.

18.
Arq. bras. oftalmol ; 87(2): e2021, 2024.
Article in English | LILACS-Express | LILACS | ID: biblio-1527835

ABSTRACT

ABSTRACT Purpose: This study aimed to evaluate the long-term safety and efficacy of neodymium-doped yttrium aluminum garnet (Nd:YAG) vitreolysis for symptomatic vitreous floaters as it remains a controversial procedure due to insufficient robust evidence in the literature for the maintenance of the results and absence of adverse effects. Methods: This is an observational extension to the previously presented prospective, randomized, double-blind clinical trial. Eight of thirteen subjects who underwent vitreolysis with YAG laser returned for a late reevaluation, 18 months after the procedure, to evaluate the efficacy and safety of the procedure. Results: All patients maintained the improvement in symptomatology noted after the procedure, with 25% showing complete improvement and a similar proportion (37.5%) reporting significant or partial improvement. Objective improvement in opacity was similar to that found at 6 months follow-up. The NEI-VFQ 25 quality of life questionnaire showed no statistically significant difference in responses between the 6th and 18th month. No adverse effects were noted on clinical examination or reported by patients. Conclusion: Vitreolysis efficacy observed at 6 months of follow-up was maintained until the eighteenth month, with all patients reporting improvement from the pre-procedure state. No late adverse effects were noted. A larger randomized clinical trial is needed to confirm the safety of the procedure.


RESUMO Objetivos: Avaliar a segurança e eficácia a longo prazo da vitreólise com Nd:YAG laser para moscas volantes sintomáticas, uma vez que permanece como um procedimento controverso devido a falta de evidência científica robusta sobre a manutenção dos resultados e ocorrência de efeitos adversos. Métodos: Este estudo é uma extensão observacional de um ensaio clínico prospectivo, randomizado, duplo cego, previamente publicado. Oito de treze pacientes que foram submetidos a vitreólise com YAG laser foram acompanhados para uma reavaliação tardia, dezoito meses após o procedimento, para avaliar a eficácia e segurança do procedimento. Resultados: Todos os pacientes mantiveram a melhora na sintomatologia notada ao final do procedimento original, com 25% dos casos apresentando melhora completa, e uma proporção semelhante (37,5%) demonstrando melhora significativa ou parcial. A melhora objetiva na opacidade foi similar ao achado no seguimento original de 6 meses. O questionário de qualidade de vida NEI-VFQ 25 não demonstrou diferença estatisticamente significativa nas respostas entre o sexto e o décimo oitavo mês de acompanhamento. Nenhum efeito adverso foi notado no exame clínico ou reportado pelos pacientes. Conclusão: A eficácia da vitreólise observada ao sexto mês do acompanhamento foi mantida até o décimo oitavo mês, com todos os pacientes notando algum grau de melhora quando comparado ao estado pré procedimento. Nenhum efeito adverso tardio foi notado. Um ensaio clínico randomizado maior é necessário para confirmar a segurança do procedimento.

19.
Arq. bras. oftalmol ; 87(2): e2021, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1527837

ABSTRACT

ABSTRACT Due to the development of complications and the biocompatibility and scarcity of transplant donor tissues, artificial corneas, which can be used for the rehabilitation of optical functions, have been developed. The current study aimed to analyze the visual rehabilitation effects of the Boston type I keratoprosthesis, Boston type II keratoprosthesis, Aurolab keratoprosthesis, osteo-odonto-keratoprosthesis, and tibial bone keratoprosthesis. Results showed that the Boston type I keratoprosthesis was the most effective for visual rehabilitation in patients with moist ocular surfaces. The Aurolab keratoprosthesis had a lower efficacy for visual rehabilitation. Nevertheless, it is still a viable option for individuals in economically restricted countries. In patients with dry eyes, the Boston type II keratoprosthesis was associated with the best visual rehabilitation. However, the final visual acuity of patients who received osteo-odonto-keratoprosthesis and tibial bone keratoprosthesis implantation was not evaluated as the necessary information was not available.


RESUMO Em decorrência de complicações, da biocompatibilidade e da escassez de tecido doador para transplantes de córnea natural, foram elaboradas córneas artificiais que são potenciais para reabilitar funções ópticas. Nessa perspectiva, objetivou-se a análise da eficácia da reabilitação visual entre os implantes: Boston tipo I, Boston tipo II, Aurolab, osteo-odonto-ceratoprótese e ceratoprótese de Osso Tibial. De modo geral, a princípio observou-se uma tendência de melhoria da Best-corrected visual acuity em todos os tipos de lentes, mas considerável queda durante acompanhamento a longo prazo. O dispositivo com melhor reabilitação visual em pacientes com superfícies oculares úmidas é a Boston tipo I, seguida pela Aurolab, que é economicamente viável em países emergentes. Ao considerar pacientes com olhos secos, o implante de Boston tipo II apresenta maior reabilitação visual. Por fim, em virtude de não apresentarem dados equiparáveis, as lentes osteo-odonto-ceratoprótese e de osso tibial não puderam ser analisadas.

20.
Arq. bras. oftalmol ; 87(5): e2022, 2024. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1527847

ABSTRACT

ABSTRACT Purpose: To explore the therapeutic effects of orthokeratology lens combined with 0.01% atropine eye drops on juvenile myopia. Methods: A total of 340 patients with juvenile myopia (340 eyes) treated from 2018 to December 2020 were divided into the control group (170 cases with 170 eyes, orthokeratology lens) and observation group (170 cases with 170 eyes, orthokeratology lens combined with 0.01% atropine eye drops). The best-corrected distance visual acuity, best-corrected near visual acuity, diopter, axial length, amplitude of accommodation, bright pupil diameter, dark pupil diameter, tear-film lipid layer thickness, and tear break-up time were measured before treatment and after 1 year of treatment. The incidence of adverse reactions was observed. Results: Compared with the values before treatment, the spherical equivalent degree was significantly improved by 0.22 (0.06, 0.55) D and 0.40 (0.15, 0.72) D in the observation and control groups after the treatment, respectively (p<0.01). After the treatment, the axial length was significantly increased by (0.15 ± 0.12) mm and (0.24 ± 0.11) mm in the observation and control groups, respectively, (p<0.01). After the treatment, the amplitude of accommodation significantly declined in the observation group and was lower than that in the control group, whereas both bright and dark pupil diameters significantly increase and were larger than those in the control group (p<0.01). After the treatment, the tear-film lipid layer thickness and tear break-up time significantly declined in the two groups (p<0.01). Conclusions: Orthokeratology lens combined with 0.01% atropine eye drops can synergistically enhance the control effect on juvenile myopia with high safety.


RESUMO Objetivo: Explorar os efeitos terapêuticos das lentes de ortoceratologia combinados com colírio atropina 0,01% em miopia juvenil. Métodos: Um total de 340 pacientes com miopia juvenil (340 olhos) tratados entre 2018 e Dezembro de 2020 foram divididos em Grupo Controle (170 casos com 170 olhos, lentes de ortoceratologia) e Grupo Observação (170 casos com 170 olhos, lentes de ortoceratologia combinadas com colírio atropina 0,01%). A acuidade visual melhor corrigida para longe, acuidade visual melhor corrigida para perto, dioptria, comprimento axial, amplitude de acomodação, diâmetro da pupila brilhante, diâmetro da pupila escura, espessura da camada lipídica da película lacrimal e tempo de ruptura do rasgo foram medidos antes do tratamento e 1 ano depois. A incidência de reações adversas foi observada. Resultados: Antes do tratamento, o grau esférico equivalente foi significativamente melhorado em 0,22 (0,06, 0,55) D e 0,40 (0,15, 0,72) D respectivamente no Grupo Observação e no Grupo Controle após o tratamento (p<0,01). Após tratamento, o comprimento axial foi significativamente aumentado em (0,15 ± 0,12) mm e (0,24 ± 0,11) mm respectivamente nos Grupos Observação e controle (p<0,01), enquanto, no grupo de observação, a amplitude de acomodação diminuiu significativamente e foi inferior a do Grupo Controle, e o diâmetro da pupila brilhante e o diâmetro da pupila escura aumentaram significativamente e foram maiores do que os do Grupo Controle (p<0,01). A espessura da camada lipídica da película lacrimal e o tempo de ruptura do rasgo diminuíram significativamente nos dois grupos (p<0,01) após o tratamento. Conclusões: As lentes de ortoceratologia combinadas com colírio atropina 0,01% podem melhorar significativamente o efeito controle em miopia juvenil com elevada segurança.

SELECTION OF CITATIONS
SEARCH DETAIL